According to the needs of different application scenarios, a nationally produced QS-02 back hanging/side hanging circulating respirator has been developed and extensively tested in water tanks, mines, and Nanning Shenglongtan, with a maximum testing depth of 200 meters.
This model has a streamlined structural design, excellent breathing performance and safety, and a unique integrated design that can easily convert the back and side hooks, meeting various diving needs such as special operations, rescue, and salvage.
Main features: The mechanical sequence needle valve reliably adjusts the oxygen supply to meet the oxygen demand of divers at different depths, and provides the best oxygen partial pressure. Even if the oxygen partial pressure monitoring system fails, it can still be used safely; The multi-functional monitoring system for oxygen partial pressure monitors oxygen partial pressure in real time and provides diving depth, time, pressure reduction information, electronic compass and vibration alarm functions. It has a user set constant oxygen partial pressure control function and provides support for multi gas pressure reduction programs and mixed gas pressure reduction algorithms. The optimized design of the gas path ensures extremely low respiratory resistance, unique automatic drainage function, and lightweight design (the whole machine includes 18.5kg gas cylinders).
The complete system includes:
1. Integrated nose, carbon fiber body
2. Pulmonary bag
3. Axial absorbent tank
4. Breathing hose and mouthpiece
5. Sequential needle valve
6. Manual/automatic gas supply valve for mixed gas
7. Gas supply kit for mixed gas regulator
8. Pure oxygen regulator gas supply kit
9.2L mixed gas cylinder
10.2L pure oxygen cylinder
11. Multi functional monitoring system for oxygen partial pressure
QS-02 Back/Side Hanging System Parameters:
diameter |
180mm
|
height |
480mm
|
width |
400mm
|
Maximum working depth |
120m
|
Diving support time
|
Greater than or equal to 300 minutes
|
Respiratory resistance
|
Under the conditions of a respiratory rate of 15 breaths per minute and a ventilation volume of 30 liters per minute
When not filled with absorbent, the average inspiratory resistance is 350 Pa and expiratory resistance is 300 Pa
When filling the absorbent, the average inspiratory resistance is 220 Pa and expiratory resistance is 380 Pa
|
Lung bag volume
|
5 liters
|
Automatic gas supply valve for mixed gas
|
Medium pressure straight through valve
|
Oxygen supply
|
Sequential needle valve controls flow rate
|
controller
|
shearwater petrel
|
Controller power supply
|
1.5V lithium battery
|
Overpressure valve
|
Unidirectional check exhaust valve
|
Oxygen sensor
|
3 of them
|
Carbon dioxide absorbent tank
|
Axial adsorption
|
Carbon dioxide absorbent
|
2.5 kg (797 sofnolime) or Beipiao Jingta calcium hydroxide
|
Mixed gas cylinder
|
2L aluminum gas cylinder
|
Pure oxygen cylinder
|
2L aluminum gas cylinder
|
Whole machine weight
|
18.5 kg (including gas cylinder, excluding carbon dioxide absorbent)
|
Usage time
|
≥ 4 hours
|
Multi functional monitoring system for oxygen partial pressure
|
Real time monitoring of oxygen sensor readings, water depth, and diving duration
|